MMC-16 APC to 2 x MTP-8 APC Breakout Cable, 16 Fibers, OS2
MMC-16 APC to 2 x MTP-8 APC Breakout Cable, 16 Fibers, OS2

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This OS2 breakout cable terminates a 16-fiber MMC APC female connector into two MTP-8 APC Elite female legs. It offers a direct single-mode fan-out for parallel-optics links that divide sixteen fibers into two eight-fiber interfaces. Factory-built harness polarity and labeled branches remove the need for a distinct cassette and its extra mated connections.

Product Highlights

  • MMC Female to MTP® Female, 16 Fibers
  • OS2 9/125μm, G.657.A1
  • MMC insertion loss ≤0.35dB, return loss ≥60dB
  • Harness Polarity wiring scheme
  • 2.5mm Plenum (OFNP) cable
  • Standard length options: 1m (3ft), 2m (7ft), 3m (10ft)

Specifications

Part Number16FMMCMTPSMF
ManufacturerHT
Connector AUS Conec MMC Female (Non-Pinned)
Connector BUS Conec MTP® Elite Female (Non-Pinned)
Polish TypeAPC to APC
Glass FiberG.657.A1
Fiber ModeOS2 9/125μm
Wavelength1310/1550nm
Fiber Count16 Fibers
PolarityHarness Polarity
Cable Outside Diameter (OD)2.5mm
Cable JacketPlenum (OFNP)
Min. Bend Radius (Optical Fiber)10mm
Min. Bend Radius (Fiber Cable)20/10D (Dynamic/Static)
Tensile Strength (Long Term)30N
Tensile Strength (Short Term)100N
Insertion Loss≤0.35dB
Return Loss≥60dB
Attenuation at 1310nm≤0.35dB/km
Attenuation at 1550nm≤0.21dB/km
Operating Temperature-10 to 60°C (14 to 140℉)
Storage Temperature-10 to 70°C (14 to 158℉)

Mapping one MMC-16 into two MTP-8 legs

The MMC side concentrates all sixteen fibers in one VSFF housing, while every MTP branch carries eight fibers. This arrangement is suitable only when the port and panel design expects the identical two-way map. Because all three connectors are female and non-pinned, the mating interfaces must offer guide pins. Confirm the necessary APC polish on each leg before connecting this assembly.

Loss planning across three connection points

The specified insertion loss is 0.35dB maximum and return loss is at least 60dB. A full link budget must provide the MMC interface, the chosen MTP branch interface and any adapters farther along the path. Keeping the two branch identities in the test report and rack records makes it easier to isolate a fault to one eight-fiber route.

Fan-out placement and standard lengths

Offered lengths are 1m (3ft), 2m (7ft) and 3m (10ft), with made-to-order lengths in feet or meters. Select a length that lets this fan-out body rest in a supported region rather than hang from the MMC port. Path the two MTP legs with gentle bends and avoid loading one branch differently from the other when dressing this cable.

Ordering and Factory Support

Specify 16FMMCMTPSMF in the two-leg OS2 breakout setup, stating total length and unit count. If branch identifiers or unequal leg lengths are needed for a specific rack layout, provide a fan-out diagram with the inquiry. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies MMC-16 APC to 2 x MTP-8 APC Breakout Cable, 16 Fibers, OS2 to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.