For data-center links that specify Generic SFP56-50G-ACC-7M23FT, this 7m (23ft) ACC assembly delivers 50G connectivity through SFP56. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.
OEM Part Number: SFP56-50G-ACC-7M23FTHT Part Number: SFP56-50G-ACC-7M23FT
| HT Part Number | SFP56-50G-ACC-7M23FT |
|---|---|
| Compatible | Generic |
| Manufacturer | HT |
| Form Factor | SFP56 |
| Max Data Rate | 50Gbps |
| Cable Type | Active Twinax |
| Max Cable Distance | Up to 7m |
| Cable Length | 7m (23ft) |
| Wire AWG | 26AWG |
| Power Consumption | ≤0.5W |
| Jacket Material | PVC |
| Storage Temperature | -40 to 85°C (-40 to 185°F) |
| Operating Temperature | 0 to 70℃ (32 to 158°F) |
| Modulation Technology | PAM4 |
| Bit Rate | 53.125 Gbps |
| Protocol | SFP56 MSA |
The rated power consumption is ≤0.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC jacket. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
This 7m (23ft) assembly is intended for routes that shorter members of the same family cannot serve comfortably. Before ordering, document the actual pathway and the space available for service access. During installation, secure the complete copper assembly and both connector housings without compressing it into an undersized bundle or leaving its weight suspended from the ports. The next shorter verified assembly is SFP56-50G-ACC-5M16FT at 5m (16ft), which is the better comparison when the managed route leaves substantial unused cable.
SFP56-50G-ACC-7M23FT is the longest of 5 verified length options in this family. Compared with SFP56-50G-ACC-5M16FT at 5m (16ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 26AWG; the stated power consumption is ≤0.5W; the jacket material is PVC.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 7m (23ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
No. It is manufactured by HT under our own manufacturer identity.
No. SFP56-50G-ACC-7M23FT refers here to 7m (23ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000