The product on this page is the 70m (230ft) version of Generic SFP+ to SFP+-10G-AOC-70M230FT, built for 10G operation with SFP+ to SFP+. Its complete AOC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.
OEM Part Number: SFP+ to SFP+-10G-AOC-70M230FTHT Part Number: SFP+ to SFP+-10G-AOC-70M230FT
| HT Part Number | SFP+ to SFP+-10G-AOC-70M230FT |
|---|---|
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Supply Voltage | 3.45 V |
| Minimum Bend Radius | 30mm |
| Cable Length | 1~300m@OM3 MMF |
| Wavelength | 850nm |
| Built-in CDR | NO |
| Transmitter Type | VSCEL |
| Receiver Type | PIN |
| Modulation | NRZ |
| Bit Error Rate | 1E-12 |
| Jacket Material | OFNP |
| Built-in FEC | NO |
| Protocols | SFF-8431,10GBASE Ethernet, Fibre Channel |
| Operation temperature | -40 to 85°C (-40 to 185°F) |
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
SFP+ to SFP+-10G-AOC-70M230FT is the longest of 3 verified length options in this family. Compared with SFP+ to SFP+-10G-AOC-50M164FT at 50m (164ft), it provides 20m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the jacket material is OFNP.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8431,10GBASE Ethernet, Fibre Channel. Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
At 70m (230ft), SFP+ to SFP+-10G-AOC-70M230FT should be planned as an extended equipment-room connection rather than a short in-rack jumper. Mark the complete vertical and horizontal route before installation, including every manager the cable will actually pass through. Support the integrated optical cable and both optical engines along that path and keep both ends free from pull loads. The next shorter verified assembly is SFP+ to SFP+-10G-AOC-50M164FT at 50m (164ft), which is the better comparison when the managed route leaves substantial unused cable.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 70m (230ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000