Cisco SFP-10G-BX80D-I Compatible 10G SFP+ Transceiver Module

Cisco SFP-10G-BX80D-I Compatible 10G SFP+ Transceiver Module

The SFP-10G-BX80D-I compatible module serves equipment requiring a 10G SFP+ interface with 1550nm-TX/1490nm-RX optics and a 80km rating. Connection is through Simplex LC. Product data, application guidance and factory verification are presented together to support data-center designers evaluate optical reach, rack integration and host compatibility together.

OEM Part Number: SFP-10G-BX80D-IHT Part Number: SFP-10G54-BX80-I

Product Highlights

  • Compatible alternative to Cisco SFP-10G-BX80D-I
  • 10G connectivity at 10.3125Gbps
  • Optical wavelength: 1550nm-TX/1490nm-RX
  • Specified reach: 80km
  • Simplex LC / SMF interface
  • Operating temperature: -40 to 85°C (-40 to 185°F)
  • Factory compatibility verification and optical performance testing before shipment

Specifications

Cisco CompatibleSFP-10G-BX80D-I
ManufacturerHT
HT Part NumberSFP-10G54-BX80-I
Form FactorSFP+
Max. Data Rate10.3125Gbps
Wavelength1550nm-TX/1490nm-RX
Max. Transmission Distance80km
ConnectorSimplex LC
MediaSMF
Transmitter TypeEML
Receiver TypeAPD
TX Power0~5dBm
Receiver Sensitivity<-23dBm
Power Budget23dB
Receiver Overload≥-7dB
Max. Power Consumption≤2W
Extinction Ratio>8.2dB
Operating Temperature-40 to 85°C (-40 to 185°F)
ProtocolsIEEE 802.3ae, SFF-8472, SFF-8431, SFF-8432, SFP+ MSA Compliant, CPRI, eCPRI10GBASE-ZR/ZW

Applications and Optical Link Design

This BiDi interface is useful where only one fiber strand is available between two sites or racks. It must be paired with the complementary wavelength direction: one end transmits on the wavelength that the other end receives. Verify the paired part number, connector polish and fiber plant before installation, and measure link loss against the specified optical budget.

The industrial temperature rating makes this version appropriate for controlled outdoor cabinets, transport nodes and other installations exposed to wider ambient temperature variation. Adequate airflow, protected cable routing and host-platform temperature limits still apply.

BiDi operation saves a fiber strand but makes wavelength orientation critical. Record the part installed at each end and check its paired receive wavelength. The 80km rating still depends on total channel loss, including connectors and splices.

Quality Assurance and Packaging

Quality control covers the optical or electrical interface, host identification and operating link. The verified unit is then individually protected and cartoned. Customer references, rack groups and project packing lists can be added for volume orders.

Optical Acceptance, Diagnostics and Handling

For this model, the specified transmit-power range is 0~5dBm; receiver sensitivity is <-23dBm; the stated optical power budget is 23dB. During commissioning, record the host diagnostic readings after the link has stabilized and compare them with those limits. DOM values are useful operational indicators, but they do not replace calibrated optical measurements when a link is marginal. Investigate unexpected loss through connector inspection, cleaning and a channel measurement before replacing the module. Before every insertion, keep dust caps in place until the patch lead is ready, avoid touching the optical end face and use an appropriate inspection and cleaning procedure. Do not look into an active optical interface.

Data-Center Optical Design and Airflow

Select the module by optical standard, reach and rack layout. Check the complete fiber channel, including panels and connectors, and keep dense bundles from blocking front-panel airflow. Account for listed power consumption and preserve enough space to remove a module without disturbing adjacent links. For this model, the principal parameters are data rate 10.3125Gbps, wavelength 1550nm-TX/1490nm-RX, rated reach 80km.

Ordering Information

When ordering, specify SFP-10G-BX80D-I, SFP-10G54-BX80-I, quantity and intended host platform. Project labels can repeat these details for receiving and asset records. Neutral labels, customer packaging and project-specific compatibility review are available on request.

Cisco Compatibility and Factory Testing

Factory verification starts with the expected SFP-10G-BX80D-I identity and finishes with an operating host link. EEPROM data, diagnostic visibility and the stated optical parameters are assessed together. Equipment model, hardware revision and software release can be reviewed before dispatch where platform behavior is uncertain.

Frequently Asked Questions

Is this an original Cisco transceiver?

No. It is an HT-manufactured compatible alternative for equipment that specifies SFP-10G-BX80D-I, not an original Cisco-branded module.

Which fiber and connector are required?

Use Simplex LC with SMF. The specified maximum reach is 80km, subject to fiber quality and total link loss.

Can it be mixed with another wavelength or reach version?

Only when the two ends share the same optical standard, wavelength plan and supported data rate. Check the exact part numbers and link budget rather than relying only on the module form factor.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, with production lead times confirmed for larger quantities. International courier, air freight and sea freight are available; customer courier accounts and nominated forwarders are accepted.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support