SC UPC to Unterminated Fiber Pigtail, 12 Fibers, Unjacketed Color-Coded, OS2 |
![]() For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This fiber pigtail terminates outside-plant or backbone cable into a connectorized panel: SC UPC to Unterminated Fiber Pigtail, OS2 glass, with a factory-polished SC UPC connector on one end and a prepared fiber strand on the other. Fusion-spliced onto the incoming cable, it turns a raw fiber path into a documented, testable port. Product Highlights
Specifications
Why pigtails remain the standard terminationA pigtail is half an interface: one end is a factory-built connector, polished and tested under procedure control; the other is a bare fiber strand ready for the splice. Fusion-splicing that strand onto the existing cable brings this connector quality of the factory to a field path. The result outperforms field-polished connectors on insertion loss, return loss and long-term stability, and it outperforms pre-terminated trunks when the path length is uncertain or the pathway is difficult to pre-measure. Fusion splicing practice that protects the budgetA good splice starts long before the splicer arcs: strip the strand cleanly, cleave square, keep the sleeve staged, and protect the completed splice in the tray with the bend radius respected. The tight-buffered 0.9mm coating on this pigtail strips in one motion and seats cleanly in standard splice sleeves. Done well, a fusion splice adds less attenuation than a connector pair and stays stable for the life of the plant. For UAE procurement, record this requirement with the project documents so the supplied configuration can be checked on arrival. Color coding as a working disciplineTwelve fibers, twelve colors, one order: the TIA-598 sequence is the only thing standing between a tidy splice tray and a crossed plant. The strands in this set observe the standard sequence, so the splicer matches colors between cable and pigtail without guesswork. When the documentation follows the identical sequence, a fault on location seven months from now is found in minutes rather than traced strand by strand. Keeping twelve-fiber splices organizedMulti-fiber splicing rewards method: entire one color fully - strip, clean, cleave, splice, sleeve - before starting the next, and dress every finished strand into the tray in sequence. The color-coded set makes the pairing unambiguous, and the tray stays readable for the next technician who opens it. A tray that reads unambiguously is a tray that gets re-entered without new faults. Unjacketed and bunch constructions comparedThe unjacketed color-coded set presents twelve distinct 0.9mm strands for direct tray work - the lightest build and the easiest to dress. The bunch build gathers the twelve strands under a shared jacket that breaks out near this connector end, adding handling protection on the path between this panel and the tray. Select unjacketed where the strands stay inside a protected enclosure; select bunch where this assembly crosses open space between frames. Bend-insensitive glass in dense traysSplice trays and panel rear spaces punish fiber: tight routing, crowded dressing and the occasional hurried re-entry all bend strands beyond what legacy single-mode tolerated. The bend-insensitive grade used in this pigtail holds attenuation stable at bend radii that would fog conventional glass, which keeps the connection margin intact after the tenth tray opening, not just at commissioning. A splicing workflow that scalesProductive termination crews work to a fixed routine: mount the tray, dress this cable, splice the pigtails color by color, protect every joint, test every completed port, then close and label. With the routine fixed, a two-person crew terminates a full frame location in a predictable time, and the test record maps cleanly onto the documentation. The consistency additionally makes quality auditable - identical materials, identical sequence, identical pass criteria across each site. Sparing and kit planning for termination workPigtails belong in the termination kit in counted sets with spares: strands break, connectors get contaminated beyond recovery, and a missing spare converts a ten-minute task into a second visit. Plan one spare set per frame location, keep spare strands capped and bagged, and record which set went into which tray so replacement stock may be ordered to the identical specification. Selecting the right pigtail for the jobFive decisions define the order: this connector series must be matched to this panel, the polish must be matched to the plant, the fiber mode must be matched to this cable, the build must be matched to the path, and the count must be matched to the tray capacity. Getting all five right at order time is what turns a box of strands into a dependable termination. Where the need sits outside the standard configurations, the custom platforms cover the remaining combinations. Quality Control and TestingEach pigtail is optically tested before packing: insertion loss and return loss are verified on every terminated leg, and the ferrule end faces are inspected for scratches and contamination. The strands ship coiled, capped and bagged, with the test results offered on specify. Ordering and Factory SupportRefer to this pigtail by connector, polish, fiber mode, fiber count and build when ordering a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, lengths or project packing - send the need with the inquiry and the factory will verify the manufacturable specification. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued. |
|||||||||||||||||||||||||||||||||||||||||
Fiber Optic UAE supplies SC UPC to Unterminated Fiber Pigtail, 12 Fibers, Unjacketed Color-Coded, OS2 to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000