QSFP28 to QSFP28-100G-ACC-9M29FT 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Active Copper Breakout Cable, 9m (29ft)

QSFP28 to QSFP28-100G-ACC-9M29FT 100G QSFP28 4 x 25G NRZ to 2 x 50G QSFP28 2 x 25G NRZ Active Copper Breakout Cable, 9m (29ft)

This QSFP28 to QSFP28-100G-ACC-9M29FT compatible ACC cable provides a 100G direct connection for Generic equipment in a fixed 9m (29ft) configuration. The QSFP28 to QSFP28 assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.

OEM Part Number: QSFP28 to QSFP28-100G-ACC-9M29FTHT Part Number: QSFP28 to QSFP28-100G-ACC-9M29FT

Product Highlights

  • HT-manufactured ACC assembly in 9m (29ft)
  • 100G connectivity at 100Gbps
  • Interface configuration: QSFP28 to QSFP28
  • Fixed length and part number: 9m (29ft), QSFP28 to QSFP28-100G-ACC-9M29FT
  • Cable construction: Active Twinax
  • Conductor specification: 26AWG
  • Maximum power consumption: ≤1.5W
  • Operating temperature: 0 to 70℃ (32 to 158°F)

Specifications

HT Part NumberQSFP28 to QSFP28-100G-ACC-9M29FT
ManufacturerHT
Connector TypeQSFP28 to QSFP28
Max Data Rate100Gbps
MediaCopper
Power Consumption≤1.5W
Min. Bend Radius36.5mm
Wire AWG26AWG
Cable Length9m
Jacket MaterialPVC (OFNR)
Cable TypeActive Twinax
Commercial Temperature Range0 to 70℃ (32 to 158°F)
Modulation Format4x 25G-NRZ to Dual 2x 25G-NRZ
Application100G Ethernet
ProtocolsSFF-8665, QSFP28 MSA, SFF-8636, SFF-8679

Signal and Lane Configuration

The listed modulation format is 4x 25G-NRZ to Dual 2x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Power and Thermal Planning

The rated power consumption is ≤1.5W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 100G Ethernet. Listed interface and protocol references include SFF-8665, QSFP28 MSA, SFF-8636, SFF-8679. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP28 to QSFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Length Selection and Installation Planning

Choose QSFP28 to QSFP28-100G-ACC-9M29FT when the measured managed path justifies 9m (29ft), not simply to leave a large spare coil. Additional reach can simplify adjacent-rack routing, yet unused cable still needs bend-safe storage and ventilation clearance. Keep identification visible so this extended version is not confused with shorter spares. The next shorter verified assembly is QSFP28 to QSFP28-100G-ACC-7M23FT at 7m (23ft), which is the better comparison when the managed route leaves substantial unused cable.

Position Within the Length Range

QSFP28 to QSFP28-100G-ACC-9M29FT is the longest of 6 verified length options in this family. Compared with QSFP28 to QSFP28-100G-ACC-7M23FT at 7m (23ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 26AWG; the stated power consumption is ≤1.5W; the jacket material is PVC (OFNR).

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to QSFP28 to QSFP28-100G-ACC-9M29FT.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. QSFP28 to QSFP28-100G-ACC-9M29FT refers here to 9m (29ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.