For data-center links that specify Generic QSFP28 to 4x SFP28-100G-DAC-9M29FT, this 9m (29ft) DAC assembly delivers 100G connectivity through QSFP28 to 4x SFP28. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.
OEM Part Number: QSFP28 to 4x SFP28-100G-DAC-9M29FTHT Part Number: QSFP28 to 4x SFP28-100G-DAC-9M29FT
| HT Part Number | QSFP28 to 4x SFP28-100G-DAC-9M29FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP28 to 4x SFP28 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Active Breakout DAC |
| Cable Length | 9m (29ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 44.5mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | 1.8W |
| Modulation Format | QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G/25G Ethernet |
| Protocols | QSFP28 MSA, SFP28 MSA, SFF-8665, SFF-8679, SFF-8472, SFF-8402 |
The listed modulation format is QSFP28-4x 25G-NRZ SFP28-1x 25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
QSFP28 to 4x SFP28-100G-DAC-9M29FT is the longest of 5 verified length options in this family. Compared with QSFP28 to 4x SFP28-100G-DAC-7M23FT at 7m (23ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 44.5mm; the stated power consumption is 1.8W; the jacket material is PVC (OFNR).
The rated power consumption is 1.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 44.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 100G/25G Ethernet. Listed interface and protocol references include QSFP28 MSA, SFP28 MSA, SFF-8665, SFF-8679, SFF-8472, SFF-8402. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP28 to 4x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The extended 9m (29ft) configuration gives QSFP28 to 4x SFP28-100G-DAC-9M29FT a specific place in the family reach range. It should not be treated as a universal substitute for every shorter order code. Match it to a documented route, protect the complete copper assembly and both connector housings during handling and retain the part-number label for later maintenance. The next shorter verified assembly is QSFP28 to 4x SFP28-100G-DAC-7M23FT at 7m (23ft), which is the better comparison when the managed route leaves substantial unused cable.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 9m (29ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is manufactured by HT under our own manufacturer identity.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords