For data-center links that specify Generic QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT, this 1.5m (5ft) DAC assembly delivers 200G connectivity through QSFP-DD to 8x SFP28. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.
OEM Part Number: QSFP-DD to 8x SFP28-200G-DAC-1.5M5FTHT Part Number: QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT
| HT Part Number | QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 8x SFP28 |
| Max. Data Rate | 200Gbps |
| Media | Copper |
| Cable Type | Passive Breakout DAC |
| Minimum Bend Radius | 22.5mm |
| Wire AWG | 30AWG |
| Cable Length | 1.5m (5ft) |
| Jacket Material | PVC (OFNR) |
| Max. Power Consumption | 0.1W (QSFP-DD End)0.1W (SFP28 Per End) |
| Modulation Format | QSFP-DD-8x 25G-NRZSFP28-25G-NRZ |
| DDM/DOM | Not Supported |
| Commercial TemperatureRange | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472 |
The listed modulation format is QSFP-DD-8x 25G-NRZSFP28-25G-NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The rated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PVC (OFNR) jacket, minimum bend radius 22.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA, SFF-8432, IEEE 802.3bs-200GAUI-8, IEEE802.3by-25GAUI, CMIS 4.0, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.
The QSFP-DD to 8x SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The additional half metre beyond a one-metre assembly gives QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT useful routing flexibility when the ports are not directly aligned. It can accommodate a different rack unit or a short service loop, but excess cable should be dressed loosely rather than folded into a tight coil.
QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT occupies the middle of this family between QSFP-DD to 8x SFP28-200G-DAC-1M3FT at 1m (3ft) and QSFP-DD to 8x SFP28-200G-DAC-2M7FT at 2m (7ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 22.5mm; the stated power consumption is 0.1W (QSFP-DD End)0.1W (SFP28 Per End); the jacket material is PVC (OFNR).
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT associated with 1.5m (5ft) throughout the order and receiving record.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. QSFP-DD to 8x SFP28-200G-DAC-1.5M5FT refers here to 1.5m (5ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000