QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Active Optical Breakout Cable, 20m (66ft)

QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT 200G QSFP-DD 8 x 25G NRZ to 8 x 25G SFP28 25G NRZ Active Optical Breakout Cable, 20m (66ft)

This QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT compatible AOC cable provides a 200G direct connection for Generic equipment in a fixed 20m (66ft) configuration. The QSFP-DD to 8x 25G SFP28 assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.

OEM Part Number: QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FTHT Part Number: QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT

Product Highlights

  • HT-manufactured AOC assembly in 20m (66ft)
  • 200G connectivity at 206.24Gbps (8x 25.78Gbps)
  • Interface configuration: QSFP-DD to 8x 25G SFP28
  • Fixed length and part number: 20m (66ft), QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT
  • Cable construction: OM3
  • Maximum power consumption: QSFP-DD <4W,SFP28 <1W
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberQSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT
ManufacturerHT
Form FactorQSFP-DD to 8x 25G SFP28
Max. Data Rate206.24Gbps (8x 25.78Gbps)
Cable Length20m
Cable TypeOM3
Minimum Bend Radius30mm
Power ConsumptionQSFP-DD <4W,SFP28 <1W
Transmitter TypeVSCEL
Receiver TypePIN
Modulation FormatNRZ
BER5E-5
Inbuilt FECNo
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsQSFP-DD MSA V5.0,SFP28 MSA,CMIS V4.0,SFF-8472

Signal and Lane Configuration

The listed modulation format is NRZ. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Breakout Port Mapping

The QSFP-DD to 8x 25G SFP28 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

With 20m (66ft) available, the installer has more routing freedom but also more cable to control. Determine where any remaining service loop will be stored, preserve the stated bend radius and keep the loop away from sharp edges and hot exhaust. The integrated optical cable and both optical engines should remain accessible for inspection and removal. Within this family, QSFP-DD to 8x 25G SFP28-200G-AOC-15M49FT is shorter at 15m (49ft), while QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT is the next longer choice at 25m (82ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT occupies the middle of this family between QSFP-DD to 8x 25G SFP28-200G-AOC-15M49FT at 15m (49ft) and QSFP-DD to 8x 25G SFP28-200G-AOC-25M82FT at 25m (82ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is QSFP-DD <4W,SFP28 <1W.

Power and Thermal Planning

The rated power consumption is QSFP-DD <4W,SFP28 <1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP-DD MSA V5.0,SFP28 MSA,CMIS V4.0,SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep QSFP-DD to 8x 25G SFP28-200G-AOC-20M66FT associated with 20m (66ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes receive activity and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Can different brands be connected with the same assembly?

Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.