This OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT compatible DAC cable provides a 400G direct connection for Generic equipment in a fixed 2.5m (8ft) configuration. The OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT
| HT Part Number | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 400Gbps |
| Media | Copper |
| Cable Type | Passive DAC |
| Minimum Bend Radius | 40.5mm |
| Max. Power Consumption | 0.1W Per End |
| Cable Length | 2.5m (8ft) |
| Wire AWG | 28AWG |
| Temperature Range | 0 to 70°C (32 to 158°F) |
| Jacket Material | PVC |
| Protocols | OSFP MSA, IEEE 802.3cd 100GBase-CR2, CMIS 4.0 |
| Modulation Format | 8x 50G-PAM4 |
The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
The 2.5m (8ft) version is useful when a two-metre run would leave insufficient working slack. Before installation, check the complete horizontal and vertical path so that OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT reaches both ports without tension at either connector.
OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2M7FT at 2m (7ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-3M10FT at 3m (10ft). It adds 0.5m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is 0.1W Per End; the jacket material is PVC.
The rated power consumption is 0.1W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3cd 100GBase-CR2, CMIS 4.0. Confirm that the host firmware and port configuration support the same operating mode.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-DAC-2.5M8FT refers here to 2.5m (8ft). Every other verified length has a separate part number and page in the length list.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000