OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Ethernet Active Optical Cable, 20m (66ft)

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT 400G OSFP 8 x 50G PAM4 IHS/Finned Top Ethernet Active Optical Cable, 20m (66ft)

The product on this page is the 20m (66ft) version of Generic OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT, built for 400G operation with OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top). Its complete AOC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.

OEM Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FTHT Part Number: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT

Product Highlights

  • HT-manufactured AOC assembly in 20m (66ft)
  • 400G connectivity at 400Gbps
  • Interface configuration: OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
  • Fixed length and part number: 20m (66ft), OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT
  • Cable construction: Active Optical Cable
  • Maximum power consumption: 10W Per End
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT
ManufacturerHT
Form FactorOSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)
Max. Data Rate400Gbps
Cable Length20m (66ft)
Cable TypeActive Optical Cable
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVCSEL
Receiver TypePIN
Max. Power Consumption10W Per End
Modulation Format8x 50G-PAM4
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Jacket MaterialOFNP
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
Inbuilt FECYes
Application400G Ethernet
ProtocolsCMIS V4.0, OSFP MSA

Signal and Lane Configuration

The listed modulation format is 8x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 400G Ethernet. Listed interface and protocol references include CMIS V4.0, OSFP MSA. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Length Selection and Installation Planning

The installation review for a 20m (66ft) link should include pathway length, support points, connector access and future maintenance. Route the integrated optical cable and both optical engines before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. Within this family, OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-15M49FT is shorter at 15m (49ft), while OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT is the next longer choice at 25m (82ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT occupies the middle of this family between OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-15M49FT at 15m (49ft) and OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-25M82FT at 25m (82ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 10W Per End; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 10W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT associated with 20m (66ft) throughout the order and receiving record.

Generic Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.

Frequently Asked Questions

Is this an original equipment manufacturer cable?

No. It is manufactured by HT under our own manufacturer identity.

Does this order code cover multiple lengths?

No. OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top)-400G-AOC-20M66FT refers here to 20m (66ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.