For data-center links that specify Generic OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1M3FT, this 1m (3ft) DAC assembly delivers 400G connectivity through OSFP (IHS/Finned Top) to 2x QSFP56. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.
OEM Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1M3FTHT Part Number: OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1M3FT
| HT Part Number | OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1M3FT |
|---|---|
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to 2x QSFP56 |
| Max. Data Rate | 400Gbps |
| Cable Length | 1m (3ft) |
| Wire AWG | 30AWG |
| Minimum Bend Radius | 34.5mm |
| Max. Power Consumption | 0.1W (OSFP End) 0.1W (QSFP56 Per End) |
| Cable Type | Passive Twinax |
| Jacket Material | PVC |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | OSFP MSA, CMISRev4.0, IEEE802.3cd, SFF-8436, SFF-8665, SFF-8679, SFF-8636 |
| Application | 400G Ethernet |
| Modulation Technology | PAM4 |
The rated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 34.5mm; the stated power consumption is 0.1W (OSFP End) 0.1W (QSFP56 Per End); the jacket material is PVC.
This assembly uses 30AWG conductors, PVC jacket, minimum bend radius 34.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 400G Ethernet. Listed interface and protocol references include OSFP MSA, CMISRev4.0, IEEE802.3cd, SFF-8436, SFF-8665, SFF-8679, SFF-8636. Confirm that the host firmware and port configuration support the same operating mode.
The OSFP (IHS/Finned Top) to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
At 1m (3ft), OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1M3FT is a practical choice for direct connections within one rack. Route the cable along the intended management path rather than pulling it diagonally across adjacent connectors, and leave enough clearance for insertion, removal and front-panel airflow.
OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1M3FT occupies the middle of this family between CAB-O-2Q-400G-1M at 1m (3ft) and OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1.5M5FT at 1.5m (5ft). It adds 0m over the shorter option for extra routing clearance, while the next longer version adds another 0.5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to OSFP (IHS/Finned Top) to 2x QSFP56-400G-DAC-1M3FT.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.
No. It is manufactured by HT under our own manufacturer identity.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000