
This MFS1S90-H003E compatible AOC cable provides a 200G direct connection for NVIDIA/Mellanox equipment in a fixed 15m (49ft) configuration. The 2x QSFP56 to 2x QSFP56 assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: MFS1S90-H003EHT Part Number: MFS1S90-H003E
| HT Part Number | MFS1S90-H003E |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MFS1S90-H015E |
| Manufacturer | HT |
| Form Factor | 2x QSFP56 to 2x QSFP56 |
| Max Data Rate | 200Gbps |
| Cable Length | 15m (49ft) |
| Cable Type | OM3 |
| Wavelength | 850nm |
| Minimum Bend Radius | 30mm |
| Transmitter Type | VCSEL |
| Receiver Type | PIN |
| Power Consumption | ≤4.35W |
| Jacket Material | OFNP |
| CDR (Clock and Data Recovery) | TX & RX Built-in CDR |
| Modulation Format | PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Protocols | QSFP56 MSA, SFF-8665, SFF-8636, InfiniBand HDR |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The 2x QSFP56 to 2x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Longer assemblies require disciplined cable dressing. For MFS1S90-H003E at 15m (49ft), use the intended managers rather than a diagonal route across the rack, and leave enough space to release each connector. Any service allowance should be loose and supported, with the integrated optical cable and both optical engines protected throughout the path. Within this family, MFS1S90-H003E is shorter at 10m (33ft), while MFS1S90-H003E is the next longer choice at 20m (66ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
MFS1S90-H003E occupies the middle of this family between MFS1S90-H003E at 10m (33ft) and MFS1S90-H003E at 20m (66ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is ≤4.35W; the jacket material is OFNP.
The rated power consumption is ≤4.35W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include QSFP56 MSA, SFF-8665, SFF-8636, InfiniBand HDR. Confirm that the host firmware and port configuration support the same operating mode.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Quantity and any labeling instructions should be attached specifically to MFS1S90-H003E.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFS1S90-H003E.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
No. MFS1S90-H003E refers here to 15m (49ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000