NVIDIA/Mellanox MFA1W00-W020 Compatible 400G QSFP-DD 8 x 50G PAM4 Ethernet Active Optical Cable, 20m (66ft)

NVIDIA/Mellanox MFA1W00-W020 Compatible 400G QSFP-DD 8 x 50G PAM4 Ethernet Active Optical Cable, 20m (66ft)

For data-center links that specify NVIDIA/Mellanox MFA1W00-W020, this 20m (66ft) AOC assembly delivers 400G connectivity through QSFP-DD to QSFP-DD. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.

OEM Part Number: MFA1W00-W020HT Part Number: MFA1W00-W020

Product Highlights

  • Compatible alternative to NVIDIA/Mellanox MFA1W00-W020
  • 400G connectivity at 400Gbps
  • Interface configuration: QSFP-DD to QSFP-DD
  • Fixed length and part number: 20m (66ft), MFA1W00-W020
  • Cable construction: OM4
  • Maximum power consumption: 8W Per End
  • Minimum bend radius: 30mm
  • Operating temperature: 0 to 70°C (32 to 158°F)

Specifications

HT Part NumberMFA1W00-W020
NVIDIA/Mellanox Ethernet CompatibleMFA1W00-W020
ManufacturerHT
Form FactorQSFP-DD to QSFP-DD
Max. Data Rate400Gbps
Cable Length20m (66ft)
Cable TypeOM4
Wavelength850nm
Minimum Bend Radius30mm
Transmitter TypeVSCEL
Receiver Type850nm PIN
Max. Power Consumption8W Per End
Jacket MaterialOFNP
CDR (Clock and Data Recovery)TX & RX Built-in CDR
Modulation FormatPAM4
DDM/DOMSupported
Commercial Temperature Range0 to 70°C (32 to 158°F)
ProtocolsIEEE 802.3cd, OIF-CEI-04.0, QSFP-DD MSA,QSFP-DD-CMIS-rev4p0
Inbuilt FECNo
Application8x 50G-PAM4

Signal and Lane Configuration

The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Length Selection and Installation Planning

The extended 20m (66ft) configuration gives MFA1W00-W020 a specific place in the family reach range. It should not be treated as a universal substitute for every shorter order code. Match it to a documented route, protect the integrated optical cable and both optical engines during handling and retain the part-number label for later maintenance. Within this family, MFA1W00-W015 is shorter at 15m (49ft), while MFA1W00-W025 is the next longer choice at 25m (82ft); comparing those two boundaries helps avoid both tension and unnecessary slack.

Position Within the Length Range

MFA1W00-W020 occupies the middle of this family between MFA1W00-W015 at 15m (49ft) and MFA1W00-W025 at 25m (82ft). It adds 5m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is 8W Per End; the jacket material is OFNP.

Power and Thermal Planning

The rated power consumption is 8W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is 8x 50G-PAM4. Listed interface and protocol references include IEEE 802.3cd, OIF-CEI-04.0, QSFP-DD MSA,QSFP-DD-CMIS-rev4p0. Confirm that the host firmware and port configuration support the same operating mode.

Integrated Optical Assembly

The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep MFA1W00-W020 associated with 20m (66ft) throughout the order and receiving record.

NVIDIA/Mellanox Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, receive activity and diagnostic indications are reviewed together with the established link.

Frequently Asked Questions

Is this an original NVIDIA/Mellanox cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MFA1W00-W020.

Does this order code cover multiple lengths?

No. MFA1W00-W020 refers here to 20m (66ft). Every other verified length has a separate part number and page in the length list.

Are separate transceivers or patch leads required?

No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.

Can excess cable be folded into a compact bundle?

No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.

Shipping and Lead Time

Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.