The product on this page is the 3m (10ft) version of NVIDIA/Mellanox MCP7F60-W03, built for 400G operation with QSFP-DD to 4x QSFP56. Its complete ACC construction simplifies the physical link, and the sections below cover the exact specification, rack-integration considerations and factory verification for this individual order code.
OEM Part Number: MCP7F60-W03HT Part Number: MCP7F60-W03
| HT Part Number | MCP7F60-W03 |
|---|---|
| Manufacturer | HT |
| Form Factor | QSFP-DD to 4x QSFP56 |
| Max Data Rate | 400Gb/s |
| Cable Length | 3m |
| Cable Type | Active Twinax |
| Minimum Bend Radius | 70mm |
| Wire AWG | 30 AWG |
| Jacket Material | PVC |
| Power Consumption | <0.1W |
| Modulation Format | PAM4 |
| Inbuilt FEC | No |
| Operating Temperature Range | 0 to 70°C (32 to 158°F) |
| Inbuilt FEC | QSFP-DD MSASFF-8679SFF-8636 |
The listed modulation format is PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30 AWG; the minimum bend radius is 70mm; the stated power consumption is <0.1W; the jacket material is PVC.
The rated power consumption is <0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30 AWG conductors, PVC jacket, minimum bend radius 70mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The QSFP-DD to 4x QSFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
MCP7F60-W03 is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is MCP7F60-W04 at 4m (13ft), adding 1m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep MCP7F60-W03 associated with 3m (10ft) throughout the order and receiving record.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP7F60-W03.
No. MCP7F60-W03 refers here to 3m (10ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000