For data-center links that specify NVIDIA/Mellanox MCP2M00-A005AM, this 5m (16ft) DAC assembly delivers 25G connectivity through SFP28 to SFP28. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.
OEM Part Number: MCP2M00-A005AMHT Part Number: MCP2M00-A005AM
| HT Part Number | MCP2M00-A005AM |
|---|---|
| NVIDIA/Mellanox (Ethernet) Compatible | MCP2M00-A005AM |
| Manufacturer | HT |
| Connector Type | SFP28 to SFP28 |
| Max Data Rate | 25Gbps |
| Minimum Bend Radius | 28mm |
| Wire AWG | 26AWG |
| Cable Length | 5m (16.4ft) |
| Jacket Material | PVC (OFNR) |
| Typical Power Consumption | ≤0.5W |
| Power Supply | 3.3V |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000 |
| Application | 25G Ethernet, Data Center, 5G Wireless |
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 28mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The 5m (16ft) length gives MCP2M00-A005AM more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the DAC specification and host support must still match the intended link.
MCP2M00-A005AM is the longest of 7 verified length options in this family. Compared with MCP2M00-A003 at 3m (10ft), it provides 2m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 28mm; the jacket material is PVC (OFNR).
The intended application is 25G Ethernet, Data Center, 5G Wireless. Listed interface and protocol references include IEEE 802.3, SFP28 MSA, SFF-8402, Infiniband, EIA 364-1000. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 5m (16ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCP2M00-A005AM.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000