This MCA4J80-N005 compatible ACC cable provides a 800G direct connection for NVIDIA/Mellanox equipment in a fixed 5m (16ft) configuration. The OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: MCA4J80-N005HT Part Number: MCA4J80-N005
| HT Part Number | MCA4J80-N005 |
|---|---|
| NVIDIA/Mellanox InfiniBand Compatible | MCA4J80-N005 |
| Manufacturer | HT |
| Form Factor | OSFP (IHS/Finned Top) to OSFP (IHS/Finned Top) |
| Max. Data Rate | 850Gbps (8x 106.25Gbps) |
| Media | Copper |
| Cable Type | Active DAC (ACC) |
| Cable Length | 5m (16ft) |
| Wire AWG | 26AWG |
| Minimum Bend Radius | 59.5mm |
| Max. Power Consumption | 1.3W Per End |
| Jacket Material | PET |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Modulation Format | 8x100G-PAM4 |
| Application | 800G InfiniBand |
| Protocols | CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0 |
The listed modulation format is 8x100G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 59.5mm; the stated power consumption is 1.3W Per End; the jacket material is PET.
The rated power consumption is 1.3W Per End. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PET jacket, minimum bend radius 59.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G InfiniBand. Listed interface and protocol references include CMIS 5.0, IEEE 802.3ck, OSFP Rev5.0. Confirm that the host firmware and port configuration support the same operating mode.
The 5m (16ft) length gives MCA4J80-N005 more freedom for adjacent-rack and row-end deployments. Longer copper runs need particular attention to routing weight and bend control; the ACC specification and host support must still match the intended link.
MCA4J80-N005 is the longest of 3 verified length options in this family. Compared with MCA4J80-N004 at 4m (13ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Neutral packaging and customer-specific packing documentation are available on request.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep MCA4J80-N005 associated with 5m (16ft) throughout the order and receiving record.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is an HT-manufactured compatible alternative for equipment that specifies NVIDIA/Mellanox MCA4J80-N005.
No. MCA4J80-N005 refers here to 5m (16ft). Every other verified length has a separate part number and page in the length list.
No. This is one complete direct-attach assembly. The ends are not detachable modules and should not be separated from the cable.
No. Use a supported, bend-safe service loop and observe the listed minimum bend radius. Do not crease the cable or tighten ties around the connector boots.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Delivery can be arranged by courier, air freight or sea freight, and goods may instead be handed to an appointed forwarder or shipped on the customer’s courier account.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000