LC APC Simplex OS2 Fiber Adapter without Flange

LC APC Simplex OS2 Fiber Adapter without Flange

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. LC APC Simplex OS2 Fiber Adapter without Flange couples two LC connectors into one continuous optical route. Inside the housing, a zirconia ceramic sleeve holds the two ferrules on a common axis, keeping insertion loss low and consistent across hundreds of mating cycles. The flangeless housing snaps into this panel cutout, saving the screw hardware and speeding up panel unit.

Product Highlights

  • ≤0.2dB(Typical) Low Insertion Loss
  • Color Coded for Rapid Fiber Management
  • Protective Dust Cap Keeps Adapter’s Interior Clean from Dust
  • Plastic Buckle for Tool-less Snap-in Installation
  • Available in A Variety of Connector Types

Specifications

Connector TypeLC-LC
Body StyleSimplex
Polish TypeAPC
Fiber ModeOS2 9/125μm
Insertion Loss≤0.2dB
Durability1000 times
Mounting TypeReduced Flanged
ColorGreen
Flammability RateUL 94V-0
RoHS Compliancy StatusCompliant
Operating Temperature-40 to 85℃(-40 to 185℉)
Storage Temperature-10 to 60℃(14 to 140℉)
Dust Cap(1)Q:

Phosphor bronze and zirconia sleeves compared

Two sleeve materials dominate this adapter market. Zirconia ceramic sleeves give the tightest alignment and are the proper option for single-mode and high-behavior multimode work, where core geometry leaves no room for eccentricity. Phosphor bronze sleeves serve legacy multimode and metallic-ferrule connectors where the tolerance need is looser and the cost matters more. Matching the sleeve to the application keeps the two behavior and budget under control.

Panel cutouts and footprint discipline

Adapter panels are standardized around a handful of footprints, and the SC simplex footprint is the most common: duplex LC adapters are built to drop into the identical cutout, which is why LC and SC positions interchange freely on modern frames. Keeping to the standard footprint matters when a panel is re-loaded years later - the replacement adapter must fit the hole that is already there.

UPC and APC discipline at the adapter

This adapter has no polish of its own, but it is where polish discipline succeeds or fails: mating a UPC connector to an APC connector through any adapter damages the two end faces and wrecks return loss. Color coding exists to prevent exactly that - green housings for APC, blue for UPC single-mode - and the discipline only works when the whole plant follows it. Keep this adapter color, this connector boot color and the documentation consistent, and the mixing mistake becomes nearly impossible.

What adapter testing actually measures

An adapter contributes no signal of its own, so its test is a mating test: reference connectors mate through this adapter, and the inserted loss is recorded. A zirconia-sleeve adapter ought to add no more than 0.2 dB, and the mating must repeat that figure across cycles. Durability testing runs the mating hundreds of times and re-measures - a sleeve that wears loose announces itself as creeping loss. These figures, not the housing color, are what separates an adapter that serves for years from one that becomes the mystery fault.

Selecting the right adapter for the panel

Five decisions define this adapter order: this connector pairing must be matched to the two sides of the mating, the mounting style must fit this panel cutout, the polish color code must be matched to the plant, the sleeve material must suit the behavior grade, and the count must cover the load-out plus spares. Getting all five right at order time is what turns a bag of couplers into a dependable panel. Where the pairing crosses connector families, the hybrid range covers the common conversions.

Quality Control and Testing

Each adapter is inspected before packing: the sleeve bore is checked for alignment and surface finish, the housing latches are cycled for positive engagement, and sample matings from every production lot are measured for insertion loss. Accessories are checked for fit against the adapters they serve.

Ordering and Factory Support

Refer to this adapter by connector pairing, mounting style, polish grade and pack unit count when ordering a quotation. For configurations outside the listed options - mixed packs, panel hardware kits or project packing - send the need with the inquiry and the factory will verify the manufacturable specification. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies LC APC Simplex OS2 Fiber Adapter without Flange to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter