Customized OS2 Indoor/Outdoor Multi-Fiber Cable, LC/SC/FC/ST/Unterminated

Customized OS2 Indoor/Outdoor Multi-Fiber Cable, LC/SC/FC/ST/Unterminated

For UAE project teams, the key is to match this exact configuration to the port schedule, optical budget and delivery documentation. This custom multi-fiber cable is a pre-terminated indoor/outdoor rated unit built exactly to the setup the project specifies: connector styles and polish at every end, fiber count, jacket rating, breakout geometry and length are all chosen at order time, and the finished trunk is optically tested leg by leg before dispatch. The indoor/outdoor build carries a flame-rated jacket that additionally tolerates moisture and ultraviolet exposure, so one unit may run from an outdoor entry point directly into the building without a transition splice at the wall.

Product Highlights

  • Feature a UV Stabilized and Moisture Resistant Outer Jacket
  • Available from 1-24 Fibers with Variable Length
  • Custom Cable with Pre-terminated Connectors, Breakout Types and Pulling Eye
  • Optical Performance Test for Normal Network Connections
  • Meet the IEC 60794-1 and IEC 60794-2-20 Standard

Specifications

Connector TypeLC/SC/ST/FC/Unterminated
Polish TypeUPC/APC
Fiber ModeOS2 9/125μm
Fiber Count2 Fibers
Minimum Bend Radius20/10D (Dynamic/Static)
Breakout Outside Diameter (OD)2.0mm
Trunk Outside Diameter (OD)5.0mm
Insertion Loss≤0.3dB
Return LossUPC≥50dB, APC≥60dB
Cable TypeTight Buffered
Fiber GradeG.657.A1
Operating Temperature-20 to 60°C (-4 to 140°F)

Connector and polish discipline on single-mode links

Single-mode plants are unforgiving about polish mismatches: a UPC leg mated into an APC port destroys the return loss and may damage the two ferrules. The assembly is built with the polish specified at order time and tested as an entire trunk, so the patch side matches this panel side exactly. When documentation is unclear, the boot color tells the truth: green for APC, blue for UPC.

Bend-insensitive glass in real pathways

Backbone routes turn through tight tray corners, congested risers and crowded vertical channels. The G.657.A1 bend-insensitive fiber in the assembly tolerates a 10mm fiber bend radius, so a hurried routing decision during a night servicing window does not turn into a measurable penalty on the connection. The glass remains fully compatible with the G.652.D plant it connects to.

Breakout geometry and why it matters

The breakout is where a trunk becomes usable. While staggered legs reach a column of ports without slack piling up at one end, equal-length legs suit a straight row of adjacent ports. The 2.0mm legs survive patching-field handling; the 0.9mm version suits protected routing inside panels and cassettes. Selecting the geometry at order time means this assembly arrives matching the hardware it serves.

Pulling eye and installation practice

A pre-terminated trunk is only as good as its journey through the pathway. The optional pulling eye protects the connectorized end during the pull and keeps this trunk from twisting, which matters on long riser runs and congested trays. The deployment load rating on the datasheet is the number the pulling rope ought to respect, not the weight of the reel.

Pre-terminated versus field termination

Terminating OS2 fiber in the field means a splicer, a tray location, consumables and the craft time to do it well - multiplied by each fiber in this trunk. A pre-terminated unit moves all of that work to the factory floor, where polishing, inspection and testing happen under controlled conditions. The installer who receives this cable routes it, dresses the legs and mates these connectors; the connection is ready for light the identical hour. For multi-fiber counts the saving is not linear but compounding, because each field-terminated leg is a different chance for a rework visit.

Planning a trunk route

A multi-fiber trunk is planned once and existing once, so the planning deserves the hour it takes. Measure the path through the actual containment, note the bend space at the two ends, and decide which end gets pulled. State the pulling eye need with the order if the path is long or congested. At the far end, leave the dressing slack this panel or cassette needs - the datasheet breakout lengths are the default, and other geometries are confirmed prior to production.

Fiber Count Options

Fiber count is chosen at order time: 1 Fiber, 2 Fibers, 4 Fibers, 6 Fibers, 8 Fibers, 12 Fibers, 24 Fibers are standard options for this build. Selecting the count is a capacity decision - plan the active links, add the spares the servicing practice calls for, and this trunk arrives with each leg terminated and tested.

Length Options and Customization

Standard length options cover the common routes: 1m (3ft), 2m (7ft), 3m (10ft), 5m (16ft), 10m (33ft), 15m (49ft), 20m (66ft), 30m (98ft), 25m (82ft), with custom length offered beyond the list, including foot-based builds for projects specified in imperial units. Specifying the measured path length keeps the slack out of the tray and the strain off these connectors.

Quality Control and Testing

Each trunk is terminated with precision zirconia ferrule connectors and optically tested leg by leg before packing: insertion loss and return loss are verified on every fiber, and end-face geometry is inspected for consistent physical contact. This assembly ships with dust caps on each connector and the test results offered on specify.

Ordering and Factory Support

Refer to this setup by fiber mode, fiber count, connector pair, breakout geometry and length when ordering a quotation. For configurations outside the listed options - mixed connector families, jacket ratings, pulling eye, identification or project packing - send the need with the inquiry and the factory will verify the build prior to production. Our UAE project support can review the requirement with Shenzhen production before a formal quotation is issued.

 

Fiber Optic UAE supplies Customized OS2 Indoor/Outdoor Multi-Fiber Cable, LC/SC/FC/ST/Unterminated to data centers, ISPs and enterprises in Dubai, Abu Dhabi, Sharjah and across the Gulf region, with project support from our UAE office and production coordination from our Shenzhen factory.


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.