
This C-Z100-Q100-3M compatible DAC cable provides a 100G direct connection for Arista equipment in a fixed 3m (10ft) configuration. The SFP-DD to QSFP56 assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: C-Z100-Q100-3MHT Part Number: C-Z100-Q100-3M
| HT Part Number | C-Z100-Q100-3M |
|---|---|
| Arista Compatible | C-Z100-Q100-3M |
| Manufacturer | HT |
| Form Factor | SFP-DD to QSFP56 |
| Max. Data Rate | 100Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Cable Length | 3m (10ft) |
| Jacket Material | PVC (OFNR) |
| Minimum Bend Radius | 22.4mm |
| Wire AWG | 26AWG |
| Max. Power Consumption | 0.1W |
| Modulation Format | SFP-DD-2x 50G-PAM4QSFP56-2x 50G-PAM4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 100G Ethernet, 128G Fibre Channel |
| Protocols | SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdQSFP56: SFF-8661, SFF-8636, IEEE 802.3cd |
The listed modulation format is SFP-DD-2x 50G-PAM4QSFP56-2x 50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
The intended application is 100G Ethernet, 128G Fibre Channel. Listed interface and protocol references include SFPDD: SFP-DD MSA, SFP-DD MIS, IEEE 802.3cdQSFP56: SFF-8661, SFF-8636, IEEE 802.3cd. Confirm that the host firmware and port configuration support the same operating mode.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
C-Z100-Q100-3M is the longest of 3 verified length options in this family. Compared with C-Z100-Q100-2M at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 22.4mm; the stated power consumption is 0.1W; the jacket material is PVC (OFNR).
The rated power consumption is 0.1W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 22.4mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep C-Z100-Q100-3M associated with 3m (10ft) throughout the order and receiving record.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes link stability and diagnostic indications.
No. It is an HT-manufactured compatible alternative for equipment that specifies Arista C-Z100-Q100-3M.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000