Arista Networks C-Q200-4S50-3M Compatible 200G QSFP56 4 x 50G PAM4 to 4 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 3m (10ft)

Arista Networks C-Q200-4S50-3M Compatible 200G QSFP56 4 x 50G PAM4 to 4 x 50G SFP56 50G PAM4 Passive Copper Breakout Cable, 3m (10ft)

For data-center links that specify Arista Networks C-Q200-4S50-3M, this 3m (10ft) DAC assembly delivers 200G connectivity through QSFP56 to 4x SFP56. It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.

OEM Part Number: C-Q200-4S50-3MHT Part Number: C-Q200-4S50-3M

Product Highlights

  • Compatible alternative to Arista Networks C-Q200-4S50-3M
  • 200G connectivity at 200Gbps
  • Interface configuration: QSFP56 to 4x SFP56
  • Fixed length and part number: 3m (10ft), C-Q200-4S50-3M
  • Cable construction: Passive Breakout DAC
  • Conductor specification: 26AWG
  • Maximum power consumption: 0.1W (QSFP56 End)0.1W (SFP56 Per End)
  • Minimum bend radius: 35mm

Specifications

HT Part NumberC-Q200-4S50-3M
Arista Networks CompatibleC-Q200-4S50-3M
ManufacturerHT
Form FactorQSFP56 to 4x SFP56
Max. Data Rate200Gbps
MediaCopper
Cable TypePassive Breakout DAC
Minimum Bend Radius35mm
Wire AWG26AWG
Cable Length3m (10ft)
Jacket MaterialPVC (OFNR)
Max. Power Consumption0.1W (QSFP56 End)0.1W (SFP56 Per End)
Modulation FormatQSFP56-4x 50G-PAM4SFP56-50G-PAM4
DDM/DOMNot Supported
Commercial TemperatureRange0 to 70°C (32 to 158°F)
ProtocolsSFF-8661, SFF-8432, IEEE 802.3bs-200GAUI-4, IEEE802.3cd-50GAUI-1, SFP-8636, SFF-8472

Signal and Lane Configuration

The listed modulation format is QSFP56-4x 50G-PAM4SFP56-50G-PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.

Position Within the Length Range

C-Q200-4S50-3M is the longest of 4 verified length options in this family. Compared with C-Q200-4S50-2M at 2m (7ft), it provides 1m of additional reach for a longer vertical drop, a wider rack or an adjacent-cabinet route. Confirm that the complete path requires this length, because unused slack still needs supported, bend-safe storage.

Data-Center Design and Airflow

Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 26AWG; the minimum bend radius is 35mm; the stated power consumption is 0.1W (QSFP56 End)0.1W (SFP56 Per End); the jacket material is PVC (OFNR).

Power and Thermal Planning

The rated power consumption is 0.1W (QSFP56 End)0.1W (SFP56 Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.

Cable Construction and Routing

This assembly uses 26AWG conductors, PVC (OFNR) jacket, minimum bend radius 35mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.

Network and Protocol Considerations

The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8661, SFF-8432, IEEE 802.3bs-200GAUI-4, IEEE802.3cd-50GAUI-1, SFP-8636, SFF-8472. Confirm that the host firmware and port configuration support the same operating mode.

Breakout Port Mapping

The QSFP56 to 4x SFP56 configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.

Passive Copper Operation

A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.

Length Selection and Installation Planning

At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.

Quality Assurance and Packaging

Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.

Ordering Information

Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 3m (10ft); another length must be quoted under its corresponding part number.

Arista Networks Compatibility and Factory Testing

Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. The check includes link stability and diagnostic indications, followed by a final inspection of both ends.

Frequently Asked Questions

Is this an original Arista Networks cable?

No. It is an HT-manufactured compatible alternative for equipment that specifies Arista Networks C-Q200-4S50-3M.

Will any matching connector operate at the same speed?

Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.

What details assist a compatibility review?

Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.

How should an unused assembly be stored?

Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.

Shipping and Lead Time

Standard configurations normally ship within one to three working days, while production quantities are confirmed with the order. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.


Featured Products


UAE Fiber Optics

UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000

Popular Products

  • Fiber Optic Patch Cord
  • Fiber Optic Pigtail
  • Fiber Optic Attenuator
  • Fiber Optic Patch Panel
  • Fiber Optic Adapter

Products Datasheet

PDF catalogues of our products to download or for general inquiry, please send an email to sales@huihongfiber.com for details.

Customer Support

For customer support, please leave email to sales@huihongfiber.com, we shall reply to you as soon as possible.