For data-center links that specify Generic 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT, this 3m (10ft) ACC assembly delivers 800G connectivity through 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top). It removes separate module-and-patch-cord interfaces while retaining clear mechanical, power and compatibility details for high-density design and installation planning.
OEM Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FTHT Part Number: 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT
| HT Part Number | 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT |
|---|---|
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Active Breakout DAC (ACC) |
| Cable Length | 3m (10ft) |
| Jacket Material | PET |
| Minimum Bend Radius | 32.5mm |
| Wire AWG | 30AWG |
| Max. Power Consumption | 1.5W (800G End)/0.6W (400G Per End) |
| Modulation Format | 8x 100G-PAM4 to Dual 4x 100G-PMA4 |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Application | 800G/400G Ethernet |
| Protocols | OSFP MSA, CMIS 5.0, IEEE 802.3 ck |
The listed modulation format is 8x 100G-PAM4 to Dual 4x 100G-PMA4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
At 3m (10ft), this assembly can bridge non-aligned ports or adjacent racks while remaining a single direct-attach link. Support longer horizontal runs with suitable cable management and preserve space for cooling and future maintenance.
800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT occupies the middle of this family between 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-2M7FT at 2m (7ft) and 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-4M13FT at 4m (13ft). It adds 1m over the shorter option for extra routing clearance, while the next longer version adds another 1m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 30AWG; the minimum bend radius is 32.5mm; the stated power consumption is 1.5W (800G End)/0.6W (400G Per End); the jacket material is PET.
The rated power consumption is 1.5W (800G End)/0.6W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
This assembly uses 30AWG conductors, PET jacket, minimum bend radius 32.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is 800G/400G Ethernet. Listed interface and protocol references include OSFP MSA, CMIS 5.0, IEEE 802.3 ck. Confirm that the host firmware and port configuration support the same operating mode.
The 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep 800G OSFP (IHS/Finned Top) to 2x 400G OSFP (RHS/Flat Top)-800G-ACC-3M10FT associated with 3m (10ft) throughout the order and receiving record.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. International express, air cargo and sea freight can be selected according to destination and carton volume; customer courier accounts and nominated forwarders are also accepted.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000