
This 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2M7FT compatible DAC cable provides a 800G direct connection for Generic equipment in a fixed 2m (7ft) configuration. The 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top) assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2M7FTHT Part Number: 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2M7FT
| HT Part Number | 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2M7FT |
|---|---|
| Manufacturer | HT |
| Form Factor | 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top) |
| Max. Data Rate | 800Gbps |
| Media | Copper |
| Cable Type | Passive Twinax |
| Minimum Bend Radius | 40.5mm |
| Max. Power Consumption | 0.1W (800G End)0.1W (400G Per End) |
| Cable Length | 2m (7ft) |
| Wire AWG | 28AWG |
| Commercial Temperature Range | 0 to 70°C (32 to 158°F) |
| Jacket Material | PVC |
| Protocols | OSFP MSA, IEEE 802.3ck, CMIS v4.0 |
| Modulation Format | 8x 100G PAM4 to Dual 4x 100G PAM4 |
The listed modulation format is 8x 100G PAM4 to Dual 4x 100G PAM4. Both host interfaces must be configured for the same aggregate rate and lane arrangement. A connector that fits mechanically does not by itself guarantee that the remote port supports this encoding or breakout mode.
This assembly uses 28AWG conductors, PVC jacket, minimum bend radius 40.5mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include OSFP MSA, IEEE 802.3ck, CMIS v4.0. Confirm that the host firmware and port configuration support the same operating mode.
The 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top) configuration divides the high-speed interface into multiple lower-speed connections. Verify the upstream lane assignment, downstream port speeds and breakout setting on the host before connecting the assembly. Each branch must attach to the correct remote interface.
A passive DAC has no separate optical conversion stage. Its low-power, low-latency operation is useful for short equipment links, but the assembly must remain within the length and signaling mode accepted by both hosts.
800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2M7FT provides 2m (7ft) for connections between separated rack units or nearby equipment positions. Plan the route around cable managers and power cords, keeping the assembly free from connector strain while avoiding a large obstruction in the airflow path.
800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2M7FT is the shortest of 3 verified length options in this family. It is the preferred choice when the port positions are close and cable slack must be kept to a minimum. The next option is 800G OSFP (IHS/Finned Top) to 2× 400G OSFP (IHS/Finned Top)-800G-DAC-2.5M8FT at 2.5m (8ft), adding 0.5m for a less direct routing path; selecting it unnecessarily would leave more cable to dress.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the listed conductor specification is 28AWG; the minimum bend radius is 40.5mm; the stated power consumption is 0.1W (800G End)0.1W (400G Per End); the jacket material is PVC.
The rated power consumption is 0.1W (800G End)0.1W (400G Per End). Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Volume orders can include customer references on the labels and carton list.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. This page’s fixed configuration is 2m (7ft); another length must be quoted under its corresponding part number.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Where supported by the host, link stability and diagnostic indications are reviewed together with the established link.
No. It is manufactured by HT under our own manufacturer identity.
Not necessarily. Both hosts must support the stated rate, identification, lane mapping and any required breakout configuration; mechanical compatibility alone is insufficient.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000