This 10G-SFPP-AOC-1001 compatible AOC cable provides a 10G direct connection for Brocade equipment in a fixed 10m (33ft) configuration. The SFP+ to SFP+ assembly integrates both ends and the cable, giving data-center designers one defined product to evaluate for reach, rack layout, airflow and host compatibility.
OEM Part Number: 10G-SFPP-AOC-1001HT Part Number: 10G-SFPP-AOC-1001
| HT Part Number | 10G-SFPP-AOC-1001 |
|---|---|
| Brocade Compatible | 10G-SFPP-AOC-1001 |
| Manufacturer | HT |
| Connector Type | SFP+ to SFP+ |
| Max Data Rate | 10Gbps |
| Cable Type | OM2/OM3 |
| Cable Length | 10m (32.81ft) |
| Minimum Bend Radius | 30mm |
| Power Consumption | <0.8W |
| Jacket Material | OFNP |
| Temperature | 0 to 70°C (32 to 158°F) |
| Protocols | SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet |
The rated power consumption is <0.8W. Include this load in the host-port power and thermal budget, especially in densely populated switches. Maintain front-panel clearance and do not bundle the cable so tightly that it obstructs airflow around the connectors.
The installation review for a 10m (33ft) link should include pathway length, support points, connector access and future maintenance. Route the integrated optical cable and both optical engines before attaching both ends, and avoid dragging it across connector panels. A final inspection should confirm that no latch, boot or jacket section carries unnecessary strain. Within this family, 10G-SFPP-AOC-0701 is shorter at 7m (23ft), while 10G-SFPP-AOC-1501 is the next longer choice at 15m (49ft); comparing those two boundaries helps avoid both tension and unnecessary slack.
10G-SFPP-AOC-1001 occupies the middle of this family between 10G-SFPP-AOC-0701 at 7m (23ft) and 10G-SFPP-AOC-1501 at 15m (49ft). It adds 3m over the shorter option for extra routing clearance, while the next longer version adds another 5m. Measure the managed path and choose this version when its reach is sufficient without creating the slack associated with the longer assembly.
Select the assembly by both reach and rack layout. A direct connection removes separate module-and-patch-cord interfaces, but it still needs a bend-safe pathway and clear connector access. Keep cable bundles from blocking front-panel airflow, account for the listed interface power where applicable and choose a length that supports maintenance without leaving an unmanaged coil. For this assembly, the minimum bend radius is 30mm; the stated power consumption is <0.8W; the jacket material is OFNP.
This assembly uses OFNP jacket, minimum bend radius 30mm. These mechanical characteristics affect how the cable should be dressed behind the equipment. Avoid sharp edges, excessive ties and repeated tight bends close to the connector boots.
The intended application is determined by the host interface and protocol support. Listed interface and protocol references include SFF-8636, 1xInfiniBand QDR,DDR,SDR, 10G Gigabit Ethernet. Confirm that the host firmware and port configuration support the same operating mode.
The optical engines and fiber are permanently integrated into this AOC. There are no detachable optical modules to clean or exchange. Handle the complete assembly by its connector housings and cable, and keep both ends matched to the same interface specification.
Each cable receives connector inspection and a functional link check before it is coiled with bend-safe slack and packed. Protective materials shield the connector housings during transport. Rack or project labels are available to keep length, part number and installation destination aligned. Standard protective packing is used by default, with project documentation arranged when requested.
Provide the OEM reference, HT part number, fixed length and quantity, together with the intended host interfaces. Rack-based quantities and packaging instructions can be included for larger deployments. Other lengths are separate products and should be entered on their own order lines. Keep 10G-SFPP-AOC-1001 associated with 10m (33ft) throughout the order and receiving record.
Compatibility confirmation combines host identification with actual link establishment and diagnostic checks. The assembly is prepared for the stated OEM reference rather than selected only by connector shape. For a new data-center deployment, the equipment model, port mode and software release provide the most useful basis for a pre-order review. Both connectors are examined before the operating test, which includes receive activity and diagnostic indications.
No. It is an HT-manufactured compatible alternative for equipment that specifies Brocade 10G-SFPP-AOC-1001.
Provide the equipment manufacturer, model, port type, hardware revision and software release, together with the OEM reference, required length and quantity.
Protect both connector ends, keep the cable in a loose bend-safe coil and retain its part-number label so the length and compatibility identity remain traceable.
Only where both hosts explicitly support the complete interface and compatibility arrangement. Document each end and select the appropriate brand-specific product when required.
Available stock is generally dispatched within one to three working days after order confirmation, with production lead times advised for larger quantities. Worldwide courier services are available, with air or sea freight for consolidated shipments; freight-collect delivery and coordination with a customer’s logistics provider can be arranged.
800G TransceiversOSFP and QSFP-DD modules for AI data center networks
400G QSFP-DDSR8, DR4, FR4 and LR4 modules and cables
100G QSFP28SR4, CWDM4, LR4 and ER4 transceivers
DAC CablesDirect attach copper cables from 10G up to 800G
AOC CablesActive optical cables for rack-to-rack links
MTP/MPO Trunk Cables8F to 144F multi fiber trunk and harness cables
Fiber Patch CablesOS2, OM3, OM4, OM5 jumpers with LC, SC, FC, ST connectors
Armored Patch CablesStainless steel tube protected fiber patch cords
UAE office: Abu Dhabi,Al khaleej Al Arabi
Factory add: ZYT industrial area, Shiyan, Baoan district, Shenzhen, China 518000